Type DTR-2C DTR-4C
Rating Voltage AC220V(60Hz), DC24V
Voltage variable range AC : 85% ~ 120%
DC : 92% ~ 120%
range of used temperature -10¡É ~ 50¡É
Ambient humidity 40% ~ 85% RH
Rating load AC 250V.5A (Resistance Load) AC 250V. 3A (Resistance Load)
Operation method ON RELAY
Time error Error in voltage Within ¡¾5%
Error in Set Within ¡¾10%
Error in Temperature ¡¾4% Within, 20¡É Base
Withstand voltage AC 1500V 1minute(Between charging metal part and non-charging metal part)
Power consumption AC : ¡Ö 1VA / DC : ¡Ö 1.2W
The output Power 2a2b 4a4b
Applicable socket DP-21T(For PCB) DR-MY2 DP-41T(For PCB) DR-MY4
 
Maximum time Range of control time Maximum time Range of control time
1 SEC 0.044 sec ~ 1 sec 3 MIN 6.5 sec ~ 3 min
3 SEC 0.09 sec ~ 3 sec 6 MIN 13.5 sec ~ 6 min
6 SEC 0.37 sec ~ 6 sec 12 MIN 23.2 sec ~ 12 min
12 SEC 0.5 sec ~ 12 sec 30 MIN 63 sec ~ 30 min
30 SEC 1.5 sec ~ 30 sec 60 MIN 138 sec ~ 60 min
60 SEC 2.3 sec ~ 60 sec